TIZIANO BIELLI

CURRENT TRANSFORMERS ACCURACY:

Current transformers are devices used to scale down currents that otherwise would be to high to measure. In this page I'll show the results of some performance tests that I did over some current transformers.

TEST PARAMETERS:

When chosing an AC current transformer accuracy is only one of the many parameter of interest. Depending on your application you might consider:

CTs:

SCT013-000 Openable 100A CT (New small core version):

Specs: (Datasheet)
I1nI2nRatioAccuracyLinearityFrequency
?? 100 A50 mA20001 %?? 0.2 %50 - 1000 Hz
SCT013-000_NEW-Small-Core-Vs-Big-Core

Popular, low price, CT with mediocre accuracy. These new units are unable to meet their specifications (probably due to the smaller core).

(3 units tested)

SCT013-000_NEW-Test@I SCT013-000_NEW-Saturation

SCT013-000 Openable 100A CT (Old big core version):

Specs: (Datasheet)
I1nI2nRatioLinearityFrequency
100 A50 mA20003 %50 - 1000 Hz
SCT013-000-Sizes

Popular, low price, CT with mediocre accuracy.

(1 unit tested)

SCT013-000-Test@I SCT013-000-Test@I SCT013-000-Saturation SCT013-000-DC-Saturation-Vs-Burden SCT013-000-Insertion-Saturation

CTKD-10 Openable 75A CT:

Specs:
I1nI2nLinearityRatioPhase angle ErrorFrequency
75 A??37.5 mA1 %2000<1 °50 - 2000 Hz
CT-Sizes

Good quality, compact, affordable, and accurate openable CT.<

(1 unit tested)

CTKD-10-Test@I CTKD-10-Test@I CTKD-10-Saturation

ZEMCTK05 Openable 50A CT:

Specs: (Datasheet)
I1nI1maxI2nLinearityRatioPhase angle Error
50 A70 A16.67 mA0.5 %3000<1.5 °
CT-Sizes

Good quality, compact, affordable, and accurate openable CT.

(2 units tested)

ZEMCTK05-Test@I ZEMCTK05-Test@Vout ZEMCTK05-Saturation

ZMCT103C PCB Mount 10A CT:

Specs: (Datasheet)
I1nI2nLinearityRatioPhase angle Error
10 A10 mA0.2 %1000<0.25 °
CT-Sizes

Affordable, accurate PCB mount CT.

(over 5 units tested)

ZMCT103C-Test@I ZMCT103C-Test@I ZMCT103C-Saturation ZMCT103C-DC-Saturation-Vs-Burden ZMCT103C-Insertion-Saturation

ZMCT102 PCB Mount 20A CT:

Specs: (Datasheet)
I1nI2nLinearityRatioPhase angle Error
20 A10 mA0.2 %2000<0.25°
CT-Sizes

Affordable, accurate PCB mount CT.

ZMCT102-Ratio@I ZMCT102-Saturation

Published: 2023-10-00, Last edit: 2024-02-11